Offer
Axial flow fan WL-SIGMA 650
Axial flow fan WL-SIGMA 650 is designed for independent/separate ventilation of mining excavations (e.g. in coal mines, cooper mines). Axial flow fan WL-SIGMA 650 can operate as forcing fan, also as exhaust fan in auxiliary dedusting air-ducts or as forcing fan in auxiliary cooling air-ducts.
Axial flow fan WL-SIGMA 650 can be applied in underground mining methane and non-methane excavations, considered as level “a”, “b” and “c” area exposed to danger of methane explosion, as well as grade “A” and “B” danger of coal dust explosion. Axial flow fan has been classified as Group I, category M2 due to its application in areas exposed to danger of explosion (according to directive 2014/34/UE).
TECHNICAL CHARACTERISTICS | |
Nominal volumetric flow (Q) [m3/s] | 8,8 |
Nominal pressure increase (P) [Pa] | 2970 |
Motorpower [kW] | 37 |
Whirling arm’s speed [rpm] | 2954 |
Fan diameter [mm] | 650 |
Workplace temperature [°C] | up to 40 |